E. condec continuous output, F. demand output – Fairbanks FB2255 Series Instrument PC2255 PC Software Utility Program User Manual
Page 69

Appendix 1: Data Output Formats
01/13
69
51297 Rev. 1
E. Condec Continuous Output
<STX><P><WWWWWWW><U><G><M><CR>
P = Polarity
space = positive weight
- = negative weight
W = Displayed weight
U = Units
L = pounds
K = kilograms
G = Gross; N = Net
M = Motion
Leading zeros are suppressed
F. Demand Output
Activated by the receipt of a
<CR>.
Gross Weight – No Motion – decimal points included
<SP> <W> <W> <W> <W> <W> <W> <SP> <l> <b> <SP> <SP> <G>
<R> <SP> <SP> <CR> <LF> <EOT>
Gross Weight – Motion – decimal points included
<SP> <W> <W> <W> <W> <W> <W> <SP> <l> <b> <SP> <SP> <g>
<r> <SP> <SP> <CR> <LF> <EOT>
Net Weight – No Motion – decimal points included
<SP> <W> <W> <W> <W> <W> <W> <SP> <l> <b> <SP> <SP> <N>
<T> <SP> <SP> <CR> <LF> <EOT>