The following drawing shows correct placement of ground rods.

Above example #3: Double / Double

1: Clean all ground rod end(s) with abrasive to assure a good electrical connection. Keep all
ground straps untwisted, clear of standing water, with a drip loop, and as short as possible.
Secure the strap to the ground rods with the provided clamp and coat with grease.
Cover the connections to protect from condensation.

2: Connections to the weighbridge are installed by bolting to the provided bracket at the end
of each Scale Module. Scrape / sand enough paint / coating away to make a good electrical
connection, and coat with grease AFTER the connection has been made.

3: Ground rod #5 should be located near the interface conduit. It is used to connect to the
isolated ground of the Pit Power Supply (PPS) Acc 2001-1 only.

4: #1, ,2, 3, 4, and 5 Ground Rods are provided. These should be installed and correctly
connected with ground braid to the Anti-creep assy's with the provided hardware. Refer to
illustrations 50614_5, 50614_6, and Appendix VII. Ground rod connections 6, 7, and 8 are
not shown and are not provided by Fairbanks. Refer to 2-K: Grounding on page 30 for further
details.

2

1

3

4

5

Conduit

Instrument

Conduit to

= Ground Rod

X

between Modules

Single Module

Single Module

50614_8 A

1

4

5

Conduit

Instrument

Conduit to

= Ground Rod

X

between Modules

Single Module

Double Module

50614_9 A

2

3

Above example #1: Single / Single

Above example #2: Single / Double

Conduit

Instrument

Conduit to

= Ground Rod

X

between Modules

Double Module

Double Module

50614_10 A

1

4

5

2

3

Advertising