Fairbanks 2000 SERIES Rocker Column Railroad Scale User Manual
Page 37

03/10
37
50614 Rev. 5
Appendix V: Tolerances:
Load Cell Grout Plates, level within 0.015" per Foot
Appendix VI: Loadcell Specifications:
Type:
LCF-HR4020-4A
COC
#97078 / Class III L, Single: 10,000 d
Safe Load Limit:
150% of Rated Capacity.
Capacity:
110,000 LB.
Height: 7
"
Input Resistance:
1150 ohms
Output Resistance:
1000 ohms
Insulation Resistance:
10 giga ohms (1000 meg ohms)
Calibration:
2 mV/V
Cable Length:
15 feet
Minimum Verification Intervals (V MIN):
50K lb:
1.5 lb
100K lb:
3.0 lb
200K lb:
6.0 lb
Wiring:
Excitation (+) = Green
Excitation (-) = Black
Output (+) = White
Output (-) = Red
Appendix VII: Ground Rod Kit Packing List:
Assy #
Description
60811
Copper Plated Ground Rod: 3/4" X 8 '
65061
Ground Rod Clamp
79385
Ground Braid Clamp
11296
Braid, Ground Shield, 5/8 ID #8
58618
Ground Rod Cap
79386
Hex Cap Screw 5/16-18 X 1 1/2"
54224
5/16-18 Hex nut
54760
5/16" Spring Lock Washer