CAUTION:

Never allow the fill pump to operate without liquid. Running the pump dry will cause premature
wear or damage to the pump and is not covered under warranty.

8. It is highly sugested that the operator wear industrial work gloves when disconnecting the CQC-HD

from the vehicle. Close the drain valve on the black drain hose after the engine is turned off.

9. Disconnect the CQC-HD from the vehicle. Carefully reconnect the upper radiator hose to the

radiator and securely clamp.

10. Remove the vehicle’s radiator cap and/or overflow bottle cap. Remove clamp from the flexible

overflow tube. Top off the radiator and overflow bottle using the remaining coolant in the fill
container. Turn the fill pump on, and while holding the green fill hose over
the radiator’s opening, slowly open the fill valve to allow the top off coolant
to flow. Also, fill the vehicle’s coolant overflow bottle to the proper level.
Return both caps and secure.

11. Start the engine of the vehicle and check for leaks.

Draining the Waste Coolant Drum

1. Remove the red hose from the waste coolant drum (located in the back of

the machine) and place it into a receiving container (Figure 8).

2. Insert the red drain hose (wand attachment) into the opening on the waste

coolant drum until it reaches the bottom (Figure 9).

3. Turn on the drain pump (located on the front right side of the unit).

4. Allow the pump to run until all liquid is removed from the waste coolant drum.

5. Turn off the drain pump and return the red hoses to their original positions.

CAUTION:

Never allow the pump to operate without liquid. Running the pump dry will cause premature
wear or damage the pump and is not covered under warranty.

!

!

10.

Figure 8

Figure 9

Advertising