Hex wench

(supplied)

HANDSHOWER INSTALLATION (For 2064.901 only)

Drop SPRAY ESCUTCHEON (1) through the fourth hole of the tub ledge (12" max from SPOUT

center) with SPRAY ESCUTCHEON (1) directed towards tub center. Be sure RUBBER RING (2)

is properly seated in SPRAY ESCUTCHEON (1). Install RUBBER WASHER (3), BRASS WASHER (4)

and LOCKNUT (5) from underside of ledge.

Secure SPRAY ESCUTCHEON (1) by tightening LOCKNUT (5).

Install SEAL (9) and connect HOSE (10) to outlet nipple at the bottom of TEE (7). Tighten firmly.

Slip SHOWER HOSE (8) with COUPLING NUT through SPRAY

HOLDER (6) and SPRAY ESCUTCHEON (1). Note: SPRAY

HOLDER (6) must be seperate from ESCUTCHEON (1) to

pass HOSE (8) through ESCUTCHEON.(1)

Insert SEAL (9) into SHOWER HOSE (8). Connect HOSE (8)

to HOSE (10).

Install SEAL (9) and connect HAND SHOWER (11) to

SPRAY HOSE (8).

When not in use, HANDSHOWER should be seated
in the HOLDER.

NOTE

Before the bathroom is completely finished, you may

want to remove spout, handshower, and handles to

avoid damage during construction.

To remove handles, reverse steps in section 4.

To remove SPOUT (1), proceed as follows:

Unthread LIFT ROD KNOB (2) and remove.

Remove PLUG BUTTON (3) and remove SET SCREW (4) using
4mm  hex wrench supplied.

Lift SPOUT (1) off SHANK (5) carefully and remove RUBBER
RING (6).
Unthread SHANK SLEEVE (7) and remove from SHANK (5).

Reverse sequence to re-install SPOUT (1). Be sure RUBBER
RING (6) is properly seated in its recess at the base of the
SPOUT (1). Make certain SET SCREW (4) is properly aligned
and tight so that SPOUT (1) is locked in place.

6

1

2

3

5

7

8

10

9

9

9

11

1

8

4

3

2

4

6

6

5

7

VIEW "A"

VIEW "A"

7

MAKE WATER SUPPLY CONNECTIONS

8

9

7A

With HANDLES in OFF position, turn on

WATER SUPPLIES and check all connections

for leaks.

Operate both HANDLES to flush water lines

thoroughly.

Connect HOT water supply to LEFT INLET

UNION (1) and COLD water supply to

RIGHT INLET UNION (2). Pipe connections

are 3/4" NPT. Use sealant or Teflon tape

on pipe connections.

Do not solder directly to valve body.

TEST INSTALLED FAUCET

3/4" X 3/4" NPT UNION

(NOT SUPPLIED)

HOT

COLD

3/4" NPT

HAND

SHOWER

TRANSFER KNOB

3/4" NPT

2

1

Lift HAND SHOWER from HOLDER, direct spray

into tub. Lift TRANSFER KNOB to check HAND

SHOWER and HOSES for leaks.

Turn handles "off" and replace HAND SHOWER.

IMPORTANT: It is strongly recommended that access be
provided for all enclosed mechanical parts to this system.

M 9 6 8 8 3 0 R e v . 1 . 4

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.