Kasco Marine 5.3E(H)J User Manual

Page 3

Advertising
background image

3

Pin Insert (Installed on Stub Cord)

Pin Insert

Main Body

Gland

Gland Nut

Socket Insert (User Installed)

Socket insert

Main Body

Gland

Gland Nut

Note:

White gland for 9-11mm O.D.
Yellow gland for 13-15mm O.D.

Assembly/Wiring Instructions
STEP ONE
Remove the socket insert from the housing of the con-
nector. There is a slot for a fl at blade screwdriver in
the center of the insert.
Note: The inserts have a LEFT HAND THREAD and
should be turned clockwise to remove.

STEP TWO
Remove the gland nut and gland from the rear of the
housing and slide on to the cable. Make sure the gland
is orientated with the stepped edge facing the gland
nut (see picture).

Stepped Edge

STEP THREE
Prepare the cable and strip wire ends as shown.

Wire Stripping

Wire Stripping

STEP FOUR
Insert the stripped wire ends into the terminals on the
back of the Pin/Socket insert and fully tighten the
wire retention screws. (Refer to fi gure for correct wire
orientation).

Single phase wiring:

Figure 5:

Wire Connections
Brown wire to terminal L
Blue wire to terminal N
Green/Yellow wire to terminal E

3 phase wiring:

Figure 6:

Wire Connections
Brown wire to terminal 1
Black wire to terminal 2
Grey wire to terminal 3
Green/Yellow wire to terminal E

After the wires have been connected securely, pull the
cable and insert back into the housing and tighten with
a screwdriver to ensure the insert is seated correctly.
Note: LEFT HAND THREAD, turn the insert counter
clockwise to tighten.

STEP FIVE
Prepare your supplied Resin Kit by removing the cap
from the resin tube and pushing the resin nozzle onto
the tube. Then twist the nozzle to lock in place.

Advertising