PROPER INSTALLATION: Each light fi xture
must be submerged at least 25mm below
the water surface for proper cooling during
operation with greater than 20W Lamp (bulb).

OBSERVATION: Operating equipment
should be observed on a regular basis (daily,
if possible) for any reduction or variation in
performance. If a change in performance is
observed, the light should be disconnected
from power and inspected for any debris
buildup. Any buildup should be removed with
a brush or pressure washer. Make sure the
lens of the light is clean to ensure the brightest
light.

WINTER STORAGE: In regions where there
is signifi cant freezing in the wintertime, the
Low Voltage Light should be removed from
the water to protect them from the expansion
pressure of the ice.

CLEANING: Low Voltage Lighting should
be removed from the water at least once per
year (at the end of the season in cold climates)
to clean the exterior of the system, especially
fi xtures. The bronze fi xture is the surface that
dissipates heat into the water and any algae,
calcium, etc. build-up will become an insulator
that blocks heat transfer. In warmer regions
it is recommended the Low Voltage Lighting
be removed and cleaned at least two to three
times per year depending on conditions. In
most cases a power washer will be suffi cient if
the fi xture and algae are still wet. Also make
sure the lens of the light fi xture is clean to
ensure the brightest light possible.

Repair services should be performed by

Kasco Marine or a Kasco trained Authorized
Repair Center. Any alterations or changes

made to Kasco units by an unauthorized
source will void the warranty. This includes
tampering with the unit and/or power cord.
Please contact Kasco Marine, Inc. for your
nearest Authorized Repair Center.

Type Y Power Cord requires replacement
ONLY by the manufacturer or an authorized
service center.

LAMPING/RELAMPING

Always disconnect power before

servicing or relamping.

Unscrew the cap and remove the lens.

1.

Remove previous lamp from the fi xture by

2.

pulling out of the socket.
Install lamp by pushing lamp pins into

3.

socket.
Seat lamp into fi xture and hold in place

4.

with included stainless steel retaining ring.
Make sure the O rings are correctly seated

5.

and reinstall the lens and cap onto the
fi xture.

Installation Instructions

PARTS INCLUDED
LLE1005

Light fi xture with 12 Volt 75W MR-16

1.

Halogen bulb and 5 meter cord (1)
Brass Screws (2)

2.

Brass Flat Washers (2)

3.

Retaining Ring (1)

4.

Mounting Bracket set (1)

5.

TOOLS & SUPPLIES NEEDED

Flat Head Screw Driver

1.

Properly sized remote transformer listed for

2.

use with submersible luminaries.

Advertising