on the Power inverter.

Tighten the nut on each DC terminal.

Insert the light plug of this cable to the fused 12V lighter plug socket.

Unit is ready for use.

Using the Battery clips cable:

CAUTION: Please be sure all the connections are tight before the use of the unit.

Attach the red ring-type connector to the positive (+) DC terminal (red) on the power
inverter and connect the black ring type connector to the negative (-) DC terminal (black)
on the Power inverter.

Attach the negative (black) clip to the negative (-) battery terminal.

Attach the positive (red) clip to the fuse or circuitry breaker of the 12V battery bank as
indicated on ‘Typical Wiring block diagram of the Power Inverter’ on page 5.

Unit is ready for use.


Test the Power Inverter:

Turn unit on by using the On/Off button on the unit. The ‘Power’ light turns on indicating the
KISAE Power Inverter is ON. AC output is now available.

Plug in a small AC load like a 25W table lamp or small appliance to the AC socket to verify
AC is available.

The unit is successfully installed and functioning properly.

4. UNIT

OPERATION

WARNING:

RISK OF EQUIPMENT DAMAGE

 Do not plug surge-protected power bars into the unit’s 120 VAC outlets. The surge protected

components on the surge-protected power bar may not like the modified sine wave output
generate by the inverter.

 Do not connect an AC power source like utility power or generator to the unit 120 VAC outlets.

Turn ON and OFF the unit

Toggle the On/Off switch to ‘ON’ position to turn unit ON.

‘Power’ indicator will turn green. 120 VAC is available.

Toggle the On/Off switch to ‘Off’ position to turn unit off. ‘Power’ indicator will turn off.


Understanding the LED indicators

‘Power’ indicator: Indicator turn on indicate unit is ON.

‘Fault’ indicator:

Indicator turns on indicate fault was detected. Unit has shutdown. To reset
unit, remove the fault condition and reset unit by using the toggle switch and
turn unit off and on again.

Understanding the fan operation
The fan on the unit will automatically turns on when it sense the internal temperature of the unit
reach to its preset level.

AC Load on Power Inverter
Although the Power Inverter can provide high surge power up to two times the rated output power,
some appliances may still trigger on the inverter protection system. A higher power inverter is
required for those appliances.
Some appliances like speed controllers found in some fans, power tools and some power tools’
AC charger may not like the modified sine wave generate by the inverter, those appliances may
not work or may be damaged if they are connected to the inverter. If you are unsure about
powering any device with the inverter, contact the manufacturer of the device.

Estimate Run time on Load

Advertising
This manual is related to the following products: