Configuration – KISAE HS 1800-60 Home Solar Kit User Manual
Page 9

Page 9
The unit is now ready to provide power to double the run time.
Tips: The second battery box is design to be stackable. Using the above procedure
can parallel multiple battery boxes.
4. CONFIGURATION
Please read the following table to fully understand unit settings and desire your own
desirable settings. Unit default setting
is “Full Automatic” (In1, Ch1, Al1).
Understanding of Unit Setting
Inverter
Setting
In0
Inverter is disabled, unit will not provide backup function when utility
power is not available
In1
Inverter is set to standby mode. Unit will provide backup function when
utility power is not available
In2
Inverter is forced to turn on even when AC utility power is available. The
inverter will only switch back to utility mode when internal battery is
getting low. With this setting, the 5A internal charger is set to Ch0 by
default.
Charger
Setting
Ch0
Internal 5A charger is disabled. The charger will not charge the internal
battery when utility AC is available.
Ch1
Internal 5A charger is enabled. Charger will automatically charge the
internal battery when AC is available.
Alarm
Setting
AL0
Audio alarm sound is disabled. Alarm will not sound when warning and
fault occur.
AL1
Audio alarm sound is enabled. Alarm sounds when warning or fault
occurs.
Unit Function Setting
Setting
Mode of
Operation
Unit Function
In1
Ch1
AL1
Full
Automatic
(Factory
default)
AC output is provide by AC utility when utility is available
Internal battery is automatically charged by the 5A
charger
AC output will automatically switch to inverter mode
power by the internal battery when utility is not available
Audio alarm is enabled and will sound when any warning
or fault occurs