The unit is now ready to provide power to double the run time.

Tips: The second battery box is design to be stackable. Using the above procedure
can parallel multiple battery boxes.

4. CONFIGURATION

Please read the following table to fully understand unit settings and desire your own
desirable settings. Unit default setting

is “Full Automatic” (In1, Ch1, Al1).


Understanding of Unit Setting

Inverter

Setting

In0

Inverter is disabled, unit will not provide backup function when utility
power is not available

In1

Inverter is set to standby mode. Unit will provide backup function when
utility power is not available

In2

Inverter is forced to turn on even when AC utility power is available. The
inverter will only switch back to utility mode when internal battery is
getting low. With this setting, the 5A internal charger is set to Ch0 by
default.

Charger

Setting

Ch0

Internal 5A charger is disabled. The charger will not charge the internal
battery when utility AC is available.

Ch1

Internal 5A charger is enabled. Charger will automatically charge the
internal battery when AC is available.

Alarm

Setting

AL0

Audio alarm sound is disabled. Alarm will not sound when warning and
fault occur.

AL1

Audio alarm sound is enabled. Alarm sounds when warning or fault
occurs.


Unit Function Setting

Setting

Mode of

Operation

Unit Function

In1

Ch1

AL1

Full
Automatic

(Factory
default)

AC output is provide by AC utility when utility is available

Internal battery is automatically charged by the 5A
charger

AC output will automatically switch to inverter mode
power by the internal battery when utility is not available

Audio alarm is enabled and will sound when any warning
or fault occurs