>25Aac and <27Aac

10 Adc

>21Aac and <26Aac

15 Adc

>20Aac and <25Aac

20 Adc

>16Aac and <21Aac

35 Adc

<20Aac 40

Adc

<16Aac 55

Adc

Manufacturing Default Setting

Fd

Reset all settings to manufacturing default settings
(40A for IC121040 or 55A for IC122055, In1, AL1, SdL, Flo, Cb3)

Understanding the Charger De-rating Current:

The charger current will be de-rated when the environment temperature reaches 60
°C (140 °F) or the internal temperature reaches the pre-set values.

Unit De-rated

Values

>90°C (194°F)

Maximum charger will de-rated
to half

>95°C (203°F)

Charger current reduced to 5A

Internal Temperature

<85°C (185°F)

Charger current recover back
to set value

>60°C (140°F)

Charger current reduced to 5A

Environment Temperature

>55°C (131°F)

Charger current recover back
to set value

Enter Function Menu for unit setting:

To enter unit Function Menu, press and hold “Power” and “Select” button together for about 5
seconds until a beep is sounded.
When you are in Function Menu:

• Press ‘Power’ button for 1 second to toggle between different Functions Menu like ‘Cu’, ‘In’,

‘AL’, ‘Sd’, ‘bAt’, ‘Cb’ and ‘Fd’ etc.

• Press ‘Select’ button for 1 second to enter Individual Function Set Menu and you can

make change to the settings.

• The unit will EXIT the Main Menu automatically if ‘Power’ and ‘Select’ buttons is not trigger

for more than 5 seconds.

When you are in Individual Function Set Menu:

• Press ‘Select’ button for 1 second to toggle between different setting values.

• Press ‘Select’ button for 5 seconds to set selected setting and exit to next Main Menu

See more details on flow chart below.