Troubleshooting, Specifications – KISAE IC122055 Inverter-Charger 2000W User Manual
Page 14
Page 14
6. TROUBLESHOOTING
To troubleshoot the unit, please note the error code displayed on the main unit and review
“Understanding the Error Codes” in section 4.
Problem Symptom
Solution
The unit is off
Turn unit ON by following the instruction in
Section 4 to turn unit ON
No output
voltage. And
Status LED is
off.
No power to unit
Check DC fuse, Disconnect switch (if
installed) and check if Branch breaker is
either blown or turned OFF
No AC output.
Status LED is
Green
GFCI is tripped
Check load and reset the GFCI
No Output.
Status LED is
in Amber
GFCI is tripped
Check error code on display
Check AC Load Sense setting
Check load and reset the GFCI
Verify the error condition and make
correction
AC Load connected must be below the AC
Load sense setting
7. SPECIFICATIONS
Note: Specifications are subject to change without notices.
Specification
IC 121040
IC 122055
Inverter
AC Output Power
1000W
2000W
AC Output Current
8.3A
16.6A
AC Surge Power (Peak)
2000W
4000W
AC Output Voltage/Frequency
120 VAC / 60 Hz
AC Output Waveform
Sinewave (<3% THD)
Nominal DC Input Voltage
12.5 VDC
No Load battery draw
< 1.5 ADC
DC Input Voltage operating range
10.5 – 15.5 VDC
Under Voltage Alarm
11.0/12.1 VDC
Under Voltage Alarm Recovery
11.3/12.3 VDC
Under Voltage Shutdown
10.5/11.8 VDC
Under Voltage Recovery
12.0/12.6 VDC
Over Voltage Shutdown
15.5 VDC
USB
USB Port
5V, 750 mA
AC Transfer Switch
Transfer Time
< 30 ms
Transfer Relay Rating
30A
AC Input Source Setting
15, 20, 30A
AC Output Port 1 (HW Connector)
30A
30A
AC Output Port 2 (HW Connector, GFCI, CB)
15A
20A
AC Output Port 3 (GFCI & CB)
15A
20A
Display
Display Panel Port
RJ12
Inverter Mode
Input Voltage, Output Power
Charger Mode
Status & Battery voltage
Charger
Charging Voltage Range
13.5 -14.4 VDC
Float Voltage Range
13.4 – 13.8 VDC
Charger Current (max)
40 ADC
55 ADC
Charger Current Setting
5,10,20,40
5,15,35,55