Ransburg, Ground cable high voltage cable, Connections to the micropak control unit – Ransburg LEPS5002 Power Supply for MicroPak User Manual

Page 13: Routing & general guidelines)

Advertising
background image

>

This manual MUST be read and thor-

oughly understood by ALL personnel who

operate, clean and maintain this equipment.

Special care should be taken to ensure

that the WARNINGS and requirements for

operating and servicing safely, are followed.

W A R N I N G

!

The LEPS5002 must be installed outside of the

hazardous location (paint booth and areas as

outlined in NFPA 33).

GROUND CABLE

HIGH VOLTAGE CABLE

(Routing & General Guidelines)

SSW-1064

Unshielded High Voltage Cable

According to OSHA standard 1910.107, (h)(5),

high voltage cable “...shall be properly insu-

lated and protected from mechanical injury or

exposure to destructive chemicals.” To facilitate

compliance with this code, the following recom-

mendations

must be followed:

1.

NEVER route cables so that they lie on the

floor or are subject to vehicular traffic.

2.

NEVER route cables from different power

supplies along parallel paths unless they are

separated by at least 18 inches.

>

Sheathing is

NOT a safe method of

protecting a cable from wear or traffic.

W A R N I N G

!

>

Do NOT make the approach to the ap-

plicator at or below floor level. Route high

voltage cables from overhead down to the

applicator. Routing the cables up and out

of the way will result in less exposure to

dirt and traffic.

C A U T I O N

!

>

Do not locate the LEPS5002 Power

Supply near or adjacent to heat producing

equipment such as ovens, high wattage

lamps, or directly below water or steam

pipes.

C A U T I O N

!

CONNECTIONS TO THE

MICROPAK CONTROL UNIT

The 74947 dust proof and liquid tight low volt-

age cable assembly connects the LEPS5002

to the control unit through the use of a quick

disconnect circular connector located on top of

the power supply. After the cable is connected

to the power supply, make sure to tighten the

nut retaining screw with light force. This cable

assembly is supplied in lengths of 30ft, 75ft and

100ft. Refer to the MicroPak service manual for

connections to the control unit.

>

Important: Make sure that the ground

wire supplied with the power supply

(Ransburg part number 70539) is con-

nected from the grounding lug, located

on the top of the power supply, to a true

earth ground.

C A U T I O N

!

3.

ALWAYS route cable along appropriate insula-

tors.

4.

ALWAYS properly support cables at least 12

inches from metal beams. The support should

be made of material that does not conduct

electricity, such as most plastics. Ransburg

part number 45773-011, standoff insulator, is

one such support.

5.

ALWAYS route cables from overhead, down

to the applicator.

LEPS5002 Power Supply - Installation

10

Ransburg

CP-98-02.3

Advertising