Figure 5: Troubleshooting Guide (Continued)

General Problem

Cause

Solution

Erratic High Voltage

Output (All Outputs)

-or-

Power Supply Continu-

ously Overloads

Erratic High Voltage

Output (Single Output)

1. Control unit bad or not

configured properly

2. Bad low voltage cable

or cable connections

1. Bad high voltage elec-

trical contact or resistor

failure

1. Refer to the MicroPak service literature

for troubleshooting procedures.

2. Make sure that the low voltage cable,

74947, is plugged into the power supply

correctly and that the electrical contacts

are clean.

Make sure that all connections to the

MicroPak Control Unit are correct and

secured at terminal blocks.

1. Switch the HV output cable to an un-

used output if available.