SPECIFICATIONS

Operating Temperature:

0°C to +55°C

Storage and Shipping

Temperature:

-40°C to +85°C

Humidity:

95% Non-Condensing

Physical Size:

5.5" tall X 7.5" wide X 3.5" deep

Environmental / Physical

Power Required:

24VDC ± .5 V @ 2.5

Amps maximum (@ sea-

level), regulated, with

over-voltage protection.

Note: For every 1000 ft. of increased elevation,

the maximum current is increased by 3%.

High Voltage Output:

24 Volts, 1Amp, Form C

relay contact

Controller Operating Range

High Voltage:

0-100kV, settable in 1kV

increments

Current:

0-150 microamps

Communication Requirements

Control and Reporting:

Ethernet IP

Note: A unique MAC ID address is hard coded

into each High Voltage Controller

. User con-trols

must be configured to recognize each unique ad-

dress.

Internal Controller

Scan Time:

1 ms (all data is taken

from a rolling average of

8 scans)

Electrical