SPECIFICATIONS
Operating Temperature:
0°C to +55°C
Storage and Shipping
Temperature:
-40°C to +85°C
Humidity:
95% Non-Condensing
Physical Size:
5.5" tall X 7.5" wide X 3.5" deep
Environmental / Physical
Power Required:
24VDC ± .5 V @ 2.5
Amps maximum (@ sea-
level), regulated, with
over-voltage protection.
Note: For every 1000 ft. of increased elevation,
the maximum current is increased by 3%.
High Voltage Output:
24 Volts, 1Amp, Form C
relay contact
Controller Operating Range
High Voltage:
0-100kV, settable in 1kV
increments
Current:
0-150 microamps
Communication Requirements
Control and Reporting:
Ethernet IP
Note: A unique MAC ID address is hard coded
into each High Voltage Controller
. User con-trols
must be configured to recognize each unique ad-
dress.
Internal Controller
Scan Time:
1 ms (all data is taken
from a rolling average of
8 scans)
Electrical
NOTES
High Voltage Controller - Introduction
7
Ransburg