Introduction, Specifications, General description – Ransburg Serial Digital Module 76911 User Manual

Page 8: Environmental / physical electrical requirements

Advertising
background image

LN-9257-07.1

5

Serial Digital Module - Introduction

INTRODUCTION

SPECIFICATIONS

Environmental / Physical

Electrical Requirements

Input Voltage:

24 VDC

Input Current:

760 mA

(All valves on)

Input Current

Protection:

Polyfuse (Auto Reset)

Temperature

Operating:

0

o

to 55

o

C

Storage:

-40

o

C to 85

o

C

Humidity:

95% Non-Condensing

(Max.)

Size:

100 x 160mm

Eurocard module,

35mm wide

Pneumatic Input

Input Pressure:

0-100 psi (0-6.8 bar)

Burst Pressure:

250 psi (17.0 bar)

Leak Rate:

1.75 SCFM (Max.)

Req. Filtration:

10 micron

Water Vapor

Content:

1.3 g/m

3

(Max.)

Oil Vapor Content:

0.1 mg/kg (Oil/Water)

(Max.)

Pneumatic Output

Module Flow Rate:

1.9 SCFM

(1 Valve On)

Valve CV Factor:

1.2 SCFM

(All Valves On)

Valve Effective Area:

0.9mm

2

GENERAL DESCRIPTION

The Serial Digital Pneumatic Module converts

electronic signals to eight pneumatic signals. it

is packaged as a Eurocard module and fits into a

Eurocard rack with a 78145 series motherboard.

When configured in retrofit mode, it plugs into a

74847 motherboard. The module has an electri-

cal connector and a quick disconnect pneumatic

connector.

The Serial Digital Pneumatic Module may be com-

manded from any of three sources:

• Serial bus

• Discrete 24 VDC inputs (new or retrofit)

• Ransburg parallel (TTL) bus (for

retrofit applications).

On the module front panel, LED’s indicate when

each valve is energized. Also, the front panel

switches provide momentary manual override for

each valve. These front panel switches can be

locked-out with an on-module switch setting or by

a signal from the electrical connector.

Advertising