Installation, General information, Location of the 9060 – Ransburg 9060 HV Classic Controller 80130-XXX User Manual
Page 18
9060 Classic High Voltage Controller - Installation
13
CP-13-06.2
GENERAL INFORMATION
 
The following section contains general infor-
mation on the installation of 9060 High Voltage 
Controller.
INSTALLATION
The 9060 Controller MUST be located
outside of the hazardous area.
The User MUST read and be familiar
with the “Safety” section of this manual. 
 
This manual MUST be read and thor-
oughly understood by ALL personnel who 
operate, clean, or maintain this equipment! 
Special care should be taken to ensure that 
the warnings and requirements of operating 
and servicing safely are followed. The user 
should be aware of and adhere to ALL local 
building and fire codes and ordinances as 
well as NFPA-33, OSHA, and all related 
country safety codes prior to installing, op-
erating, and/or servicing this equipment. 
 
Only approved applicators should be
used with the 9060 High Voltage Controller. 
 
!
W A R N I N G
DO NOT locate the Controller near or
adjacent to heat producing equipment 
such as ovens, high wattage lamps, etc. 
!
C A U T I O N
As each installation is unique, this infor-
mation is intended to provide general in-
stallation information for the 9060 Control-
ler. Consult your authorized Ransburg 
distributor for specific directions pertaining 
to the installation of your equipment. 
N O T E
The controller may be free standing on any flat 
surface or wall mounted (wall mount brackets 
not supplied) as shown in Figure 5.
Figure 5: Typical Controller Mounting
LOCATION OF THE 9060
 
Install the controller in an area outside the 
hazardous location
in accordance with feder-
al, state, and local codes. The area should 
protect the controller from the possibility of 
environmental intrusion (such as dust or mois-
ture), have ambient temperatures that do not 
exceed 40°C, and be as close to the applicator 
as possible to minimize the length of the high 
voltage cable.