HANDGUN
TRIGGER SIGNAL


Handguns use a flow switch (13742-01 or
13742-02) to provide the trigger signal. One of
the listed flow switches is mounted inside the
9060 Controller chassis via the Air Flow Switch
Connector on the side panel. When the hand-
gun trigger is pressed and flow starts, the flow
switch is activated and triggers the high volt-
age.

For reference, when replacing a flow switch,
perform the following:

1.

Turn the 9060 Controller off, disconnect
it from its AC source, and remove the
fuses.

2. Open the Controller cabinet door.

3. The flow switch should have the ground

(green) lead connected to the ground screw
on the base plate shown in Figure 13. The
trigger signal (blue) lead should be connect-
ed to the trigger signal input on the J3-5
plug header that is connected to the PC
board.

4. Verify that J5, shown on Figure 14, has the

shunt covering pins 1 and 2.

5. Secure the cabinet door, replace the fuses,

and reconnect the AC source.

ALWAYS double check that the Con-

troller is unplugged from its AC outlet
before working with any internal wiring.

!

W A R N I N G

Figure 13: Ground Screw on Base Plate

Ground Screw