Ransburg, Mounting the color changer, Grounding of the color changer – Ransburg MCV Series Module Color Changer 78011-XX User Manual
Page 14: Mcv color changer - installation

Mounting The Color Changer
There are three mounting configurations as fol-
lows (reference Figure 3):
• 5/16” clearance holes for flush mounting to
the booth wall
• 1/4” x 20 threaded holes in the end blocks
• 1/4” x 20 threaded holes in the back of the
end blocks
Figure 4: Grounding the Color Changer
Grounding of the Color Changer
For safety, the color changer MUST be grounded.
Using a 12-gauge wire, ground the output plate of
the color changer to a true earth ground. Using
an ohm meter, check for ground, testing the earth
ground to the purge assembly top plate. The
resistance should be 10 ohms or less.
Figure 3: Mounting Configurations Footprint
> The color changer MUST be properly
grounded. Proper grounding (as described
below) will prevent static charge buildup and
possible discharge from the color changer.
W A R N I N G
!
1/4-20 UNC - 2B
1/4-20 UNC - 2B
78074-00
OUTLET
ASS'Y.
78070-00
PUREGE ASS'Y.
EARTH GROUND
(TRUE)
OHMS
0
10
PURGE ASS'Y.
TOP PLATE
MCV Color Changer - Installation