Robot waterbase applicator - introduction, Power supply, Tool center point – Ransburg Evolver Water Applicator 78863-90, 78863-60 User Manual
Page 13
Robot Waterbase Applicator - Introduction
9
Figure 3: Gun Tool Center-Point Representation
Power Supply
Figure 2 shows the optional isolated fluid supply
system in line with the RWA-EFM applicators. This
supply is required to create a voltage block which is
necesary to keep the voltage from passing throughout
the entire fluid supply system when highly conductive
materials are used. Voltage is supplied to the fluid
through contact with the resistive electrode in the
gun. The resistive electrode in the gun passes back
to the voltage block where it is "blocked" or "isolated"
from traveling any further through the fluid supply
system. The fluid tube enters an opening in the end
of the robot arm. The fluid tube passes through the
robot arm to the robot manifold where the spray gun
attaches to the robot.
The RWA-EFM series spray guns operate from any
MicroPak power supply.
Tool Center Point
Figure 3 shows the tool center-point information
on both guns. Both are based upon a 10" (254mm)
target distance.
AA-03-01.1