Robot waterbase applicator - maintenance – Ransburg Evolver Water Applicator 78863-90, 78863-60 User Manual
Page 32
28
Robot Waterbase Applicator - Maintenance
12. Refer to Figure 15 to remove the isolation tubes,
fittings, and short tie rod (Steps 12, 13, 14, 15, and
16.) Remove the isolation tube [6] by screwing the
tube counter-clockwise out of the valve maifold by
hand. Remove the (2) o-rings from each end [12]
and [13].
>
This tube should be cleaned with the
appropriate solvent to clean off the mate-
rial being sprayed. Then this tube must be
cleaned with a non-polar solvent.
NOTE
13. Inspect the ID of the tubes for carbon tracking.
If any carbon tracking is seen, the tube must be
replaced. If no tracks are seen, install a generous
amount of LSCH-0009 di-electric grease on the ID
of the tube.
14. Remove the air fittings [5] and barbed fittings
[1], [2], [3], and [4]. When re-installing these fittings,
use a non-conductive pipe thread sealant on the
threads.
15. Remove short tie rod [7] by removing two screws
[8]. Remove tie rod bracket [10] by removing socket
head cap screw [9].
16. Remove shroud o-ring [11] by prying out of
groove.
AA-03-01.1