26
Robot Waterbase Applicator - Maintenance
9. To re-install the harness, align the timing mark on
plug with timing mark on plate and tighten set screw
in place. (See Figure 13.)
Figure 14: Cascade / Tie Rod Removal
10. Refer to Figure 14 for cascade removal. With a
3/8" open-end wrench, on the flats, turn the tie rod
[2] counter-clockwise. Pull the bracket [1] out of
the slots in the tie rods. Completely remove these
parts. Pull the cascade [3] completely out of the
valve manifold.
11. To re-install the cascade [3], apply a generous
amount of di-electric grease to the labrynth end
of the cascade. Insert the cascade into the valve
manifold. Turn the tie rods [2] in by hand to within
1/2" of bottoming out in the valve manifold pocket.
Install the bracket [1] into the grooves. Using the
3/8" open-end wrench, begin tightening the tie rods
down, sequencing from side to side until the tie rods
have bottomed out against the valve body.
2
1
3
1
Bracket, Cascade Mounting
1
2
Tie Rod, Long
2
3
Cascade Assembly, HP-404
1
Item #
Description
Qty.
AA-03-01.1