Chapter 4, Troubleshooting, Ensure the express xl/xlt is receiving power – ADTRAN 1200070L1 User Manual

Page 123: Power off the express xl/xlt while holding down, Continue holding the select and test buttons un, If the express xl/xlt still does not pass self, Cycle power on the express xl/xlt, leaving it o, Chapter 4 troubleshooting

Advertising
background image

61200.070L1-1

Express XL/XLT User Manual

107

Chapter 4

Troubleshooting

When the Express XL/XLT powers up, it performs an internal self-test. This
takes about 10 seconds. At the end of the test, the PWR LED should remain on.

IF SELF-TEST FAILS

If the PWR LED is not on or continuously flashes, the following steps will ver-
ify whether or not the problem can be fixed locally.

1.

Ensure the Express XL/XLT is receiving power.

2.

Power off the Express XL/XLT while holding down SELECT and TEST;
then power back up. This will reset all internal settings to their factory de-
fault.

3.

Continue holding the SELECT and TEST buttons until the Loop LED
flashes once.

4.

If the Express XL/XLT still does not pass self-test, call ADTRAN Technical
Support for assistance. See the inside back cover of this manual for infor-
mation on contacting ADTRAN.

IF THE EXPRESS XL/XLT DOES NOT READ

READY

When the Express XL/XLT has been set up and connected to a line, but the
Loop LED does not remain on after a few minutes, proceed with the following
steps:

1.

Cycle power on the Express XL/XLT, leaving it off for a minimum of two
seconds; then turn the power on for one minute to ensure the Loop LED
still doesn’t turn on.

Advertising
This manual is related to the following products: