ADTRAN 1200070L1 User Manual

Page 95

Advertising
background image

Chapter 3: Terminal Menu Operation and Structure

61200.070L1-1

Express XL/XLT User Manual

79

Samples/Time Between Changes

Write security: 3; Read security: 5
This value is the minimum time between bandwidth changes for this Connec-
tion List profile. The range is 0 to 255 seconds. The default is 60 seconds.

Connection List/Filters

The Express XL/XLT can block packets in and out of a WAN port by use of the
filters. These filters are set up on a per-Connection List profile basis. They are
set up in two steps: 1) define the types of packets that would be of interest in
the Configuration/Security/Filter Defines menu, and 2) set up the filter type
and combination of defines that will cause a packet block.

Typical example of a filter setup:

Filters/WAN-to-LAN (In)

Write security: 2; Read security: 5
The packets which come into the Express XL/XLT can be filtered in three
ways:

Disabled

(def) - Turns off packet input filtering. No incoming

packets are blocked.

Block All

- All incoming packets from the WAN are blocked

except as defined in the Filters/In Exceptions list.

Forward All

- All incoming packets from the WAN are not

blocked except as defined in the Filters/In Exceptions list.

Advertising
This manual is related to the following products: