Troubleshooting (continued) – Robinair TIF8800X Combustible Gas Detector User Manual

Page 15

Advertising
background image

Symptom

Possible Cause

Solution

Power indicator LED

does not light; tool is

non-responsive .

1) Battery pack not charged .

2) AC adapter is connected

to tool .

1) Connect AC adapter to tool

and charge battery pack . Refer

to Setup for instructions .

2) Remove AC adapter .

Battery life is less than

3 hours of operation .

1) Battery pack needs to be

conditioned .

1) To condition battery pack:

charge it fully, then operate

tool as normal until the low

battery LED illuminates.

Repeat this procedure a

minimum of 3 to 5 times .

Tool does not operate

and battery pack charge

cycle will not complete

(24+ hour charge applied

and green light does not

illuminate) .

1) Battery pack not

connected .

2) Bad battery pack .

1) Follow instructions in the Setup

section of this manual to check

that the battery pack

connection is secure .

2) Replace battery pack .
Refer to Replacement Parts

section of this manual .

Troubleshooting (continued)

Advertising