Setup – Robinair TIF8800X Combustible Gas Detector User Manual

Page 7

Advertising
background image

5

Charge the Battery Pack

Before using the gas detector for the first time, you will need to charge the

battery pack in order for the unit to function correctly .
CauTiOn: To prevent equipment damage,
• Charge the battery pack only in temperatures between 32°F and 104°F

(0°C and 40°C). Charging outside this temperature range may cause

permanent damage to the battery pack.

• Use only the AC adapter that is included with the TIF8800X to charge the

battery pack. if a replacement adapter is needed, refer

to the Replacement Parts section of this manual.

Setup

1. Place the power switch in the OFF / CHARGE

position . See Figure 2 .

2 . Plug the AC adapter (included with the TIF8800X) into

an appropriate wall outlet, and connect the charger

jack to the charge input on the tool.

See Figure 3 .

During the charge cycle, the yellow LED (CHARGE) is

illuminated . Once charging is complete, the green

LED (READY) will also illuminate.

Notes:
• Leaving the AC adapter connected to the tool after

charging will not damage the tool. However, the tool

will not operate until the AC adapter has been

disconnected.

• The battery pack is shipped pre-charged but its

condition upon arrival to the user is unknown due to

parasitic drainage that occurs during storage and

shipment. An initial charge cycle is recommended to

achieve full performance of the tool. This initial charge

will take 2-6 hours depending on the actual condition

of the battery pack. Subsequent charges (applied after

the red low-battery LED illuminates) will take

approximately 15 hours.

• New battery packs need to be conditioned before

they’re capable of optimum performance. To condition

a new battery pack: charge it fully, then operate the

tool as normal until the low battery LED illuminates.

Repeat this procedure a minimum of 3 to 5 times.

Charger

input Jack

Figure 3

Side

View

Figure 2

Power

Switch

Top

View

Advertising