Additional

Operating

Guidelines

USING THE KEYPAD

The charging station also has a unique
keypad for data entry. It uses only six
keys for sequence control, and the LCD
display indicates the operating mode.

CAUTION!

Do not operate the station

until you have filled the vacuum pump
with oil and removed the exhaust plug
from the pump’s handle, as outlined in
“Preparing the Vacuum Pump.”

START

— Press to begin the automatic

cycle after the charging station is pro-
grammed.

CONT

— Press to resume (or continue)

operations after pressing the HOLD key
(described below).

HOLD

— Press to interrupt the

automatic cycle.

REVIEW PROGRAM

— Press to review

the existing programmed data.

ENTER

— Press to enter program data

into the computer’s memory.

RESET CYCLE

— Press to access

program mode.

ADD .2 LB. REFRIG.

— Press to partially

charge the A/C system.

USING THE DISPLAY PANEL

The charging station also displays
various messages on the display panel.

CAUTION!

Do not operate the station

until you have filled the vacuum pump
with oil and removed the exhaust plug
from the pump’s handle, as outlined in
“Preparing the Vacuum Pump.”

Segment A

— Indicates in which mode

the station is operating:

PROGRAM

— The station is in the

programming mode, which allows
you to program vacuum time and
refrigerant weight or to review the
existing program.

HOLD

— The evacuation process is

complete and the vacuum pump is
off, or no refrigerant is being
charged; also HOLD is used while
changing a refrigerant tank or to
interrupt the vacuum/charging
cycles.

AUTOMATIC

— Either the vacuum

or refrigerant charging cycle is in
process.

Segment B

— Indicates the station is

either evacuating the A/C system or
charging refrigerant or the station is
ready to be programmed for one of these
two functions:

VACUUM

• With PROGRAM, indicates the

station is ready to be programmed for
evacuation.

• With AUTOMATIC, indicates the

vacuum pump is running; the num-
ber displayed counts down in sec-
onds, showing the amount of time
remaining for evacuation.

• With HOLD, indicates the vacuum

cycle is complete (if the display shows
“0.00”), or if you pressed the HOLD
key to interrupt the vacuum cycle,
indicates the remaining time the
pump runs when you press the
CONT

key.

Diagram of Keypad