Trouble- shooting tips – Robinair 34100 Automatic A-C Charging Station User Manual

Page 15

Advertising
background image

13

R-134a Smart Cart

®

Automatic A/C Charging Station

Symptom

Cause

Cure

• Station unplugged

• Plug station into power

source

• No power at wall outlet

• Locate problem with outlet or

change outlets

• Vacuum pump unplugged

• Plug pump into power source

• Vacuum time not entered

• Program required vacuum

time

• Defective vacuum pump

• Remove and replace pump

• Faulty components

• Call factory

• Transfer stopped or

• Start A/C system and pull

too slow

rest of refrigerant into system
(Step 6 in “To Use Automatic
Vacuum/Charge Cycle”)

• Tank safety strap too tight

• Loosen the safety strap

• Refrigerant supply empty

• Replace the refrigerant tank

or call factory

• Refrigerant supply empty

• Replace the refrigerant tank

• Discharge valve open

• Close discharge valve

• Low side valve closed

• Open low side valve

• Pump oil contaminated

• Flush and change pump oil

• Hose gasket damaged

• Replace gasket or hose

• Charging line loose

• Check connections

• Manifold leaking

• Check connections

• Pump’s Iso-valve closed

• Open Iso-valve

• Overloaded or broken

• Check tank weight, recali-

scale

brate if necessary, or call
factory

Trouble-
Shooting
Tips

No power when
POWER switch is on —
no display showing

Vacuum pump does not
start

Audible tone sounds
and “CHECK REFRIG-
ERANT” message
displays during
refrigerant transfer

Refrigerant doesn’t flow
or “REFRIGERANT”
message doesn’t
display

Vacuum pump runs, but
low side gauge does not
register an appropriate
vacuum

ERR5