11

R-134a Smart Cart

®

Automatic A/C Charging Station

Quick Reference Chart

Segment B Messages

VACUUM

+ PROGRAM

= Program station for vacuum

VACUUM

+ AUTOMATIC

= Vacuum pump is running

VACUUM

+ HOLD

= Evacuation complete or

interrupted vacuum cycle

REFRIGERANT

+ PROGRAM

= Program station for charge

REFRIGERANT

+ AUTOMATIC

= Station is charging A/C system

REFRIGERANT

+ HOLD

= Interrupted charging cycle

REFRIGERANT (POUNDS)

• With PROGRAM, indicates the

station is ready to be programmed
for the amount of refrigerant to be
charged into the A/C system;
on the keypad enter the charge in
pounds (or kilograms, depending on
the model you have).

• With AUTOMATIC, indicates the

station is charging refrigerant into
the A/C system; the number shown
on the display counts down, showing
the remaining amount of refrigerant
to be dispensed.

• With HOLD, indicates the HOLD key

was pressed to interrupt the charging
cycle; the number shown on the
display is the amount of refrigerant
remaining to be charged into the
system. To continue charging, press
CONT.

Use the quick reference chart above to
interpret Segment B messages.

Segment C

— Shows a number or a

coded error message on the display that
indicates the station’s operating status or
any specific problems.

NUMBER

Indicates the vacuum time in min-
utes or the refrigerant weight in
pounds (or kilograms, depending on
the model you have).

MESSAGE CODES

• CPL — Indicates the refrigerant

charging cycle is complete.

• ERR5 — Indicates an overloaded or

broken scale.

Segment D

— Indicates the transfer of

refrigerant is slow or has stopped.

If the disposable tank is empty or

the refillable tank is low , replace
the tank following the instructions in
“Installing a Refrigerant Tank.” A
small amount of refrigerant always
remains in a refillable tank.

If there is adequate refrigerant in

the tank , you need to pull the
remainder of the programmed charge
into the low side of the A/C system,
as outlined in Step 7 of “To Use
Automatic Vacuum/Charging Cycles.”

Additional
Operating
Guidelines

Diagram of Display Panel

Advertising