Operation, Evacuating the a/c system, Warning – Robinair AC375C Refrigerant Recovery, Recycle, Recharge Unit User Manual

Page 21

Advertising
background image

Recover/Recycle/Recharge Unit

19

Wear safety goggles when working with refrigerant. All hoses may contain liquid

refrigerant under pressure. Disconnect hoses using extreme caution. Read and fol-

low all warnings at the beginning of this manual before operating the unit.

1. Verify the power cord is plugged into a correct voltage outlet, and the

service hoses are connected to the A/C system.

IMPORTANT: Connect

the red service hose to the A/C system’s high side; connect the blue

service hose to the low side.

2. On the control panel, turn the unit On, and open both panel valves.
3. Press the

Menu key ( ) until the VACUUM screen displays. Press the

Arrow keys to set the amount of time desired for the vacuum. Fifteen

minutes is recommended, but the time may vary depending on environ­

mental conditions.

NOTE: The display screen shows the time as mm:ss; where mm rep-

resents minutes and ss represents seconds. Setting vacuum time to 0

(zero) will result in continuous vacuum pump operation. To exit the vacu-

um function, press the

Start/Stop key ( ).

4. Press the

Start/Stop key ( ) to begin the vacuum operation. Watch the

vacuum time on the display — the display counts down the amount of

time it will take to evacuate the A/C system.

5. When the evacuation is complete, the unit automatically shuts off, and In­

JECT OIL displays on the screen.

6. Close both panel valves on the control panel.
7. Note the pressure on the low-side gauge, and then wait five minutes.
8. Check the low­side gauge for a rise in pressure. If pressure remains sta­

ble, evacuation is complete. If there is a rise in pressure, the A/C system

may need further repairs, or the evacuation may need to be repeated.

Operation

After recovering all refrigerant from the A/C system, draining the oil from the

system, and making repairs to the A/C system, use the following steps to evac­

uate (VACUUM) the A/C system.

WARNING

Evacuating the A/C System

VACUUM 15:00

VACUUM 00.00

Caution: If the

display shows

PRESSURE EX-

ISTS, there is

pressure in the

hoses which

may damage the

vacuum pump.

You must per-

form a recovery

operation before

starting the vac-

uum operation.

Advertising