28

WARNING

High voltage electricity inside the unit has a risk of electrical shock. Disconnect the
power before opening the back door or servicing the unit.

Replacing the Filter-Drier contd.

Maintenance

9. Open the back door of the unit’s protective covering by turning the two

screws 1/4 turn counterclockwise.

Filter-Drier Location

10. Remove the strap, and disconnect the fittings from the filter-drier.

NOTE: Dispose of the filter-drier according to current local area
regulations.

11. Install the new filter-drier with the FLOW direction arrow pointing down,

tighten fittings, and secure with the strap.

12. Close and lock the back door of the unit’s plastic covering by turning the

two screws 1/4 turn clockwise.

After replacing the filter-drier, reset the filter-drier capacity. Refer to the
instructions on the next page.