energize automatically after that timer period expires. The default time is 5 seconds but it can
be changed to any value from 1 to 99 seconds.

Entering Timer Mode and Changing Timer Value:
 Enter program code on the keypad.

 Press either ‘#’ or ‘’ and the yellow light will flash.

 Enter 9- on the keypad.

 Enter a timer value on the keypad from 0-1 to 9-9 (1 to 99

seconds).

 The red light will flash twice to confirm a valid entry. If a single

flash occurs then there was an error; try the above steps again.

 Press either ‘#’ or ‘’ to exit programming mode and the yellow

light will stop flashing.

In toggle mode the relay will energize when a valid code is entered and de-energize when a valid
code is entered a second time. When you have enabled toggle mode activation of the REX input
will energize and de-energize the relay just as if a valid User Code were entered.

Entering Toggle Mode:
 Enter program code on the keypad.

 Press either ‘#’ or ‘’ and the yellow light will flash.

 Enter 9--0-0 on the keypad.
 The red light will flash twice to confirm a valid entry. If a single

flash occurs then there was an error; try the above steps again.

 Press either ‘#’ or ‘’ to exit programming mode and the yellow

light will stop flashing.


The DK-12 gives you the ability to return all the functions, including the timer, to their factory
default settings. However, all codes will remain unchanged.

Returning to Factory Default Settings:
 Enter program code on the keypad.

 Press either ‘#’ or ‘’ and the yellow light will flash.

 Enter 8-9- on the keypad.
 Enter #-# on the keypad to complete entry.

 The red light will flash twice to confirm a valid entry. If a single

flash occurs then there was an error; try the above steps again.

 Press either ‘#’ or ‘’ to exit programming mode and the yellow

light will stop flashing.


8. SUBSET CODES
When you recognize that the DK-12 accepts multiple codes of different lengths it is possible that
one code will be a subset of another. For example, suppose you programmed 1-3-3-5-8 and
then programmed 3-3-5 as another code. When you try to enter 1-3-3-5-8 you can’t complete
the entry because when the unit sees the sequence 3-3-5 it will operate. A real problem could

1

2

3

4

7

5

6

8

9

0

#

Yellow

Light

Red

Light

12 Dig

it K

eypad

1

2

3

4

7

5

6

8

9

0

#

Yellow

Light

Red

Light

12 Dig

it K

eypad

1

2

3

4

7

5

6

8

9

0

#

Yellow

Light

Red

Light

12 Dig

it K

eypad

Advertising