5.1 WIRE ROUTING THROUGH END CAP (OPTIONAL)

Drill End Cap:

 Determine which bar end cap to

feed the flexible door cord shield
into. Normally the bar wire cable
and door cord shield go to the
hinge side of door.

 Mark and/or center punch the

bottom side of the chosen end
cap at the location shown.

 Drill a 3/8” [9.5mm] diameter

hole through the wall of the end
cap.

Install Cord Shield to Cap:

 Insert the door cord shield

through the hole drilled in the
end cap.

 Secure cord shield in place

through the hole using two (2)

provided E-clips. (One to the
inside and one to the outside of
the cap).

 Install a door cord insert into

each end of the door cord shield.

 Route bar wire cable through the

cord shield.

 Install the end cap to the end of

the bar.

Install Cord Shield to Frame:

 Drill a 3/8” [9.5mm] diameter hole into the door frame at the desired position adjacent to bar

end mount.

 Position door cord cap to fully cover the 3/8” [9.5mm] diameter hole, and then mark the two

(2) mounting holes.

 Drill two (2) 1/8” [3.2mm] holes at the marked locations.

 Install door cord insert over end of bar wire cable and slide up and into the loose end of the

flexible door cord shield.

 Route wire cable through hole in frame and make electrical connections.

 Insert the end of the door cord shield into the cord cap. Ensure that the spiral grooves of the

cord shield are engaged by the teeth inside the cord cap.

 Install the door cord cap over the wire cable and door cord shield, and then secure into place

using the two (2) provided #6 screws.

OR

Install Door

Cord Insert

Here

2X #6 Mounting

Screws

Door Cord

Cap

3/8” [9.5]

Diameter Hole

2X 1/8” [3.2]

Diameter Hole

Door Cord

Insert

Right End Cap

(Bottom)

Left End Cap

(Bottom)

Advertising