Wireless outdoor siren (sm-103, optional) – SecurityMan Air-AlArm1 - User manual User Manual

Page 18

Advertising
background image

specifications:

Operating power: 9V Battery (Recommend: alkaline battery

•

Wireless Transmitting distance: ≥300ft (in open area)

•

Service life: ≤2 years

•

Monitor volume: 480ft3

•

Adding and Cancelling smoke Alarm

To Add:

Press_

•

set + Password + eNt_then.

_

• 70 + eNt+ XX + eNt

The “Learn” light will appear solid red.

Note: the “XX” indicate group number of the 24 hour defense zones, including zone 01 through zone 05.

Press the “Test Button” twice consecutively to trigger the smoke alarm sensor, the alarm host will beep in series, the “Learn” light will flash

•

five times and then turns off to indicate the smoke alarm sensor has been successfully added.

To Cancel:

Press_

•

set + Password + eNt_then.

_

• 71 + eNt+ XX + eNt

The alarm host will beep twice, the “Learn” light flash once and then turns off to indicate the smoke alarm

sensor has been successfully cancelled.

Note: the alarm host can only learn 1 wireless device (smoke Alarm sensor) at a time, a total of 4 wireless devices (sensors) to a zone/group
can be added. if 1 device is removed from a group that has 4 devices, then all 4 devices in the group will be automatically removed, and
each device(s) will have to be added again to the alarm host.

Wireless outdoor siren (sm-103, optional)

15

Please use screw

*

(G) to mount. (see page22)

Advertising