Sample Program

This sample program demonstrates step-by-step how to use the SKC Pump
Scheduler window (see page 18) to set a program:

A sampling operation requires the AirChek 2000/3000 pump to sample at a
constant fl ow of 1000 mL/min from 8:00 AM to 4:00 PM daily for one work week.
Enter the parameters as follows:

Set the fl ow rate

Click on the New Value butt on. The Scheduler
Set Flow window opens. Click on the 1000 butt on
then click on OK. “1000” appears in the Flow
Rate cell of the Program Edit Bar.

Set the start/stop date

Click on any Monday in the Calendar. The date is highlighted.
Click on the Start Date cell in the Program Edit Bar. The date
appears in the cell. Click on the Stop Date cell to enter the same
date into the Stop Date cell.

Set the start time

Click on the Clock at 8. The clock hands will point to 8:00
and it also appears in the digital display next to the Clock.
Click on the AM butt on, then click on the Start Time cell of
the Program Edit Bar; 8:00 AM appears in the cell.

Set the stop time

Click on the Clock at 4. The clock hands will point at 4:00 and
it also appears in the digital display next to the Clock. Click on
the PM butt on, then click on the Stop Time cell of the Program
Edit Bar; 4:00 PM appears in the cell. The Duration cell displays
8 hours, which is the length of the programmed operation.

Insert the program into the Pump Program Scheduler

Click on the Insert butt on. The program appears in the Pump Program
Scheduler. Note that the program is still displayed in the Program Edit
Bar. The Pump Program Scheduler has a program that tells the pump
to run at a constant fl ow of 1000 mL/min from 8:00 AM to 4:00 PM on
Monday. The same operating parameters must be entered for each
day of the week.