IS-33 Issue: 2 Date: 28.04.11 C/Note: 11256

Page 3 of 4

7.

Create a double wrapped clamp (fig 2) by feeding end of band through narrow slot
on buckle twice. Pull on clamp by hand to reduce loop diameter for faster installa-
tion on small objects. Squeeze gripper release lever and insert band as far as possi-
ble.










8. Repeatedly squeeze tension handle until handle locks against tool body indicating
correct tension. Always allow tension handle to return to its original position after
each stroke. (Fig 3) , (Fig 4).

Fig 4

Harwin North America Harwin Europe Harwin Asia
T: +1 603 893 5376 F: +1 603 893 5396 T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 T: +65 6 779 4909 F: +65 6 779 386
E:
[email protected] W: www.harwin.com E: [email protected] W: www.harwin.com E: [email protected] W: www.harwin.com.sg

Fig 3

9. Squeeze cut off handle once against tool body to lock and trim excess band. Tension
handle will release. Remove band from tool (Fig 5)

Fig 5

CAUTION: Never use band as a single wrapped clamp!

1 7/8 DIA’
MAX

TIE-DEX CLAMP DOUBLE

WRAPPED

CUT OFF
HANDLE

TENSION

HANDLE

TENSION RELEASE

LEVER