45
4. Operation Using I/O Signals
* If Parameter No. 21 (Servo-on input disable selection) is set to “1,” a servo-on signal need not be input.
Caution:
In the “Emergency stop actuated
o Turn on the power o Servo-on input o Cancel the emergency
stop” sequence, the servo will turn on up to 1542 msec after the emergency stop is cancelled.
Servo-on input
Max. 1542 msec
Emergency stop cancelled