5 monitor, Slct mode/m2 a. 00 * monitor, Monitor a. 00 servo on – IAI America RCM-P User Manual

Page 45: Monitor a. 00 in 03 son off

Advertising
background image

37

8-5 Monitor

The I/O status and current position of all controllers connected on the communications line will be

displayed.

The following is a display example of controller PCON-CY. Some of the screen may not be displayed

depending on the type of controller. Items displayed depend on the I/O pattern setting.

Slct Mode/M2

A. 00

* Monitor

Displays the current position.

Monitor A.

00

Pos 0.00N

mm

Displays the error code number.

Monitor A.

00

Error No. 000

Displays the ON/OFF status of servo.

Monitor A.

00

Servo ON

Displays the speed.

For the pulse modes of PCON-PL/PO, ACON-PL/PO

and SCON, the Screen can be changed to the pulse

(pls) display by pressing the

key.

Displays the current.

The Screen is changed to current ratio (%) display by

pressing the

key.

Monitor A.

00

Vel 00

mm/s

Monitor A.

00

Cur 0.0

mA

Displays the ST0 (retract move command) status.

Monitor A.

00

in 00 ST0

OFF

Displays the ST1 (advance move command) status.

Monitor A.

00

in 01 ST1

OFF

Displays the ST1 (intermediate point move

command) status.

Monitor A.

00

in 02 ST2

OFF

Displays the SON (servo ON command) status.

Monitor A.

00

in 03 SON

OFF

Displays the LS0 (retract end position detection)

status.

Monitor A.

00

out 00 LS0

OFF

Displays the LS1 (advance end position detection)

status.

Monitor A.

00

out 01 LS1

ON

In the Mode Select Screen, using the keys,
select Monitor and then, press the Return key.

Select the displayed item using the Return key or the

keys.

Use the

keys to change the axis number.

Advertising