Appendix

RC Data Input pendant error table

Listed on the table are RC Data Input Pendant specific error.

For error of controller, refer to the Operating Manual of each controller.

Code Message

name

Description

112

Input Incorrect Error

An incorrect value was entered in a parameter.

(Example) 9601 was entered as the serial communication speed by mistake. Reenter an

correct value.

113

114

Input Under Error

Input Over Error

The entered value is smaller than the setting range.

The entered value is larger than the setting range.

Refer to the actuator specifications or parameter table and reenter a correct value.

115

Homing Incomplete

The current position was written when home return was not yet completed.

Execute home return again.

117

No Move Data

Target position is not set under the selected position number.

Enter the target position first.

11E Pair Data Mismatch

The values indicating the magnitude relationship of a pair of data are incorrect.

(Example) The same value was entered in both the parameters for + and – soft limits.

Reenter correct values.

11F Absolute Value Error

The minimum movement toward the target position is determined by the lead length of

the drive system and resolution of the encoder.

This message indicates that the entered target value is smaller than the minimum

movement.

(Example) If the lead length is 20mm, the encoder’s resolution is 800 pulses and

accordingly the minimum movement becomes 20

÷ 800 = 0.025 mm/pulse.

In this case, this message will be displayed if 0.02mm is entered as the target

position.

121

Push search end over

The final position in push & hold operation exceeds the soft limit.

This has no negative effect if the actuator contacts the work. If the actuator misses the

work, however, the soft limit will be reached and this message is displayed as a warning.

Change either the target position or positioning band.

122

Allocate, multi-axes connect

Address was assigned when multiple axes were connected.

Assign each address only when one axis is connected.

133

Jig No. change not allowed

For PCON-C/CG, ACON-C/CG, SCON controllers, the axis number is set with the rotary

switch on the front panel. The axis number cannot be set on the RC Data Input Pendant.

180

181

182

183

Change to axis number OK

Controller initialize OK

Home Change All Clear

IO function has been changed

These messages are displayed to confirm operation.

(They do not indicate an operation error or other abnormality.)

201

Emergency Stop

An emergency stop condition was detected. (This is not an error.)

This is displayed on RCP, RCS, E-Con, RCP2, and ERC.

202

Emergency Stop

An emergency stop condition was detected. (This is not an error.)

This is displayed on PCON, ACON, SCON, and ERC2.

203

Motor voltage drop

In controller of “shut-off relay external type,” motor drive power is shut off due to opening

between MPI terminal and MPO terminal.

(Note) If this error occurs while closing between MPI terminal and MPO terminal, the

controller is considered to be in failure.

204

ABS battery voltage drop

Battery voltage drops when power is turned on.

20A During movement, Servo OFF This message indicates that the servo ON signal (SON) was turned OFF by the PLC

while the actuator was moving, and that the servo turned OFF and the movement was

disabled as a result.

20C During movement, CSTR-ON This message indicates that the start signal (CSTR) became “1” by the PLC while the

actuator was moving, and that duplicate movement commands occurred as a result.