Functional Descriptions

3-1-9 Protective Function

The functional settings are not allowed to change without the input of a password.

When the protective function is set to “effective,” the setting can be changed by inputting the password.

The setting contents monitor function can be used regardless of the protective function “effective / ineffective.”

The password should be a 4-digit number from 0 to 9. (The password of the factory setting is “0000.”)

The protective function is set on the receiver side.

3-1-10 Initialization Function

The settings can be initialized. (factory setting) (Note)

The factory setting of each function is as follows.

Function

Setting

Fixed blanking function

Ineffective

Floating blanking function

Ineffective

Auxiliary output switching function

Mode 0

Emission intensity control function

Normal mode

Muting setting

c h a n g i n g

function

Setting of the muting function on each beam channel

Effective for all beam channels

Muting input conditions

A = B

Setting of the muting lamp diagnosis function

Effective

Muting sensor output operation setting

NONO

Interlock setting changing function

Start / Restart

External devise monitor setting changing function

Effective / 300ms

Override setting changing function

60 sec.

Note: The setting of the protective function and the setting data of the copy function are not initialized.

3-1-11 Setting Contents Monitoring Function

Each setting of the

SE4D series can be monitored. The following can be monitored.

● Model No. / the number of beam channels

● Setting of the fixed blanking function (Reading out the record of the latest 5 times is possible)

● Setting of the floating blanking function (Reading out the record of the latest 5 times is possible)

● Setting of the auxiliary output switching function

● Setting of the emission intensity control function

● Setting of the muting setting changing function

(Reading out the record of the latest 5 times is possible, however, only for setting beam channel.)

● Setting of the interlock setting changing function

● Setting of the external device monitor setting changing function

● Override setting changing function

3-1-12 Override Setting Changing Function

Maximum continuous effective time set at the override function can be changed.

The maximum continuous effective time can be set in the range of 60 to 600 sec. (in units of 10 sec.).

The factory setting is 60 sec.

● When the protecting function is set to “ineffective,” the third person may change the

setting. It is recommended that the protecting function should be set to “effective” so as

not to change the setting by the third person.

● Take sufficient care not to forget the set password. In case you forget the password,

please contact us.