Function Setting

3-2-2 Floating Blanking Function

FLO1 <Effective setting of beam channel>

0: Ineffective

1: 1 beam channel setting

2: 2 beam channels setting

3: 3 beam channels setting
FLO2 <Ineffective setting of both end beam channel>

SET (Effective) : Both ends of the beam channels are not subject to the float blanking function

CLR (Ineffective) : All beam channels are subject to the floating blanking function
FLO3 <Non serial beam channel setting>

SET (Effective) : Non-serial beam channel mode

CLR (Ineffective) : Serial beam channel mode

Note: When “all sensors” is selected in the sensor selection, the setting of the floating blanking function on each

SE4D series

should be identical.

(Sub sensor 2)

Sensor selection

(All sensors)

(Main sensor)

(Sub sensor 1)

Set No. of beam channel

(Ineffective)

Input
password

Send

(Error)

To 2

OK

NG

To 2

Send

(Error)

OK

NG

(Ineffctive)

(Effctive)

(Ineffctive)

(Note)

(Effctive)

Ineffective setting

for both ends

beam channels

Setting

for

non-serial beam

channel

One beam

channel effecive

Two beam

channel effecive

Three beam

channel effecive

3. To Auxiliary
output switching
function

2. Floating blank-
ing function

key operation

: FUNCTION
: ENTER
: CANCEL
: -
: +