Function setting, 2-5 copy function – IDEC SE4D Type 4 Hand User Manual

Page 22

Advertising
background image

21

Function Setting

3-2-5 Copy Function

“****” indicates the connection state

of the system.

● “

”: Used when connected

to the

SE4D series.

*1: The setting of the relay monitor

is as follows.

When set to ineffective: CLR

When set to effective: Set time

(100 to 600ms, in units of 10ms)

*2: The override function can be set

in the range of 60 to 600 sec. (in

units of 10 sec.)

Note: The indication is on the main sensor

(CH1) only.

key operation

: FUNCTION
: ENTER
: CANCEL
: -
: +

(Override)*

2

(Note)

(Note)

Muting sensor
output operation
setting

Muting lamp
diagnosis
function setting

5. Copy function

Select function

(Upload)

(Download)

(Monitor)

Select sensor

Input
password

Check function

6. To Muting setting
changing function

(Error)

To 5

OK

NG

Receive

(Error)

To 5

OK

NG

Receive

Confirm function

of system device

Select item

(Note)

(Note)

(Note)

(Note)

Detail display

(Only for SET)

(Effective)

(Ineffective)

・・・

Keep pressing switch OK

Detail display

(Only for SET)

(Effective)

(Ineffective)

・・・

Keep pressing switch OK

Detail display

(Only for SET)

(Set beam channels)

Both ends beam

channel ineffec-

tive setting

Non-serial

beam channel

setting

(Emission intensity control)

(Input mode)

(Interlock)

(Relay monitor) *1

(Protection)

(Auxiliary output)

Fixed blanking effective
/ ineffective display

Floating blanking effective
/ ineffective display

* * * *

* * * *