The following SVS Settings dialog window will appear:

In the bottom view on the dialog window the Digital I/O pulses configuration group box shows a
numeric up-down control that can be used to change the current digital Input pulses width: values
between 10 ms and 100 ms will be accepted from the SVS sensor.

Once you are confident your configuration is completed, press the Ok button to save the configuration
on the sensor. If you press Close button, nothing will change.


Inspection switch timing

Because before the inspection is started some processing has to be done (basically we have to run a
sort of inspection on the reference image before we can go in run mode), a unique and definitive
timing of the inspection change process is not available because it will depend on the inspection time
itself.
If the inspection use very fast tools, for example Position or Width, it will be quite fast (hundred of
milliseconds), if the inspection is quite slow, for example a difficult pattern match, the delay will be
greater maybe in the 1-2 seconds range.
During the inspection switch process, the sensor stops acquiring new images and enter an idle status.
When the switch is complete, the sensor blinks once and then starts the new inspection activity.
Anyway it is possible to check the current running inspection using the Graphic User Interface.