Electric connections, Operating distances – IDEC DATAVS2 Series User Manual

Page 7

Advertising
background image

Instruction

Manual

SVS2

Series

2

2. ELECTRIC CONNECTIONS



M12 8-pole: (power supply and I/O)

pin 1 : white : digital input 1
pin 2 : brown : 24 Vdc
pin 3 : green : STROBE for external illuminator
pin 4 : yellow : output 1
pin 5 : gray : output 2
pin 6 : pink :

output 3

pin 7 : blue :

GROUND

pin 8 : red :

external trigger



M12 4-pole Ethernet: (connectivity)

pin 1: white/orange: RX+
pin 2: white/green: TX+
pin 3: orange: RX-
pin 4: green: TX-



3. OPERATING DISTANCES


Operating distance

(mm)

SVS2-12-DE-OBJ SVS2-08-DE-OBJ SVS2-06-DE-OBJ

50

17 x 12

25 x 20

42 x 30

80

25 x 20

40 x 30

60 x 41

110

33 x 25

55 x 40

80 x 55

140

45 x 35

70 x 50

98 x 69

170

53 x 38

85 x 60

118 x 83

200

60 x 50

100 x 70

138 x 92

300

90 x 65

145 x 103

201 x 140

400

121 x 82

186 x 132

265 x 189

500

150 x 110

236 x 167

330 x 232

600

185 x 130

282 x 232

385 x 270