Electric connections, Operating distances – IDEC DATAVS2 Series User Manual
Page 7
Instruction
Manual
SVS2
Series
2
2. ELECTRIC CONNECTIONS
M12 8-pole: (power supply and I/O)
pin 1 : white : digital input 1
pin 2 : brown : 24 Vdc
pin 3 : green : STROBE for external illuminator
pin 4 : yellow : output 1
pin 5 : gray : output 2
pin 6 : pink :
output 3
pin 7 : blue :
GROUND
pin 8 : red :
external trigger
M12 4-pole Ethernet: (connectivity)
pin 1: white/orange: RX+
pin 2: white/green: TX+
pin 3: orange: RX-
pin 4: green: TX-
3. OPERATING DISTANCES
Operating distance
(mm)
SVS2-12-DE-OBJ SVS2-08-DE-OBJ SVS2-06-DE-OBJ
50
17 x 12
25 x 20
42 x 30
80
25 x 20
40 x 30
60 x 41
110
33 x 25
55 x 40
80 x 55
140
45 x 35
70 x 50
98 x 69
170
53 x 38
85 x 60
118 x 83
200
60 x 50
100 x 70
138 x 92
300
90 x 65
145 x 103
201 x 140
400
121 x 82
186 x 132
265 x 189
500
150 x 110
236 x 167
330 x 232
600
185 x 130
282 x 232
385 x 270