Safety Instructions

A Micromotor Handpiece is a high speed power tool which can be dangerous
and cause serious injury if it is not used properly. NEVER operate it without
wearing eye protection.

ALWAYS wear proper eye and face protection.

NEVER use or continue to use any accessory which appears to be damaged, loose,
vibrating, bent, or out of balance. Inspect each accessory for cracks or flaws before use.

ALWAYS insert the accessory shank into the chuck of the handpiece as far as possible
in order to provide proper support and close the chuck securely.

NEVER use excessive side pressures which may tend to bend or break the shank or
arbor of an accessory. Let the speed of the accessory do the work.

WEAR a dust protector to prevent the inhalation of harmful dust or debris from
grinding, carving or other operations performed with this power tool.

DO NOT cover the ventilation slots or handpiece motor with cloth or tape. Air must
pass freely through the intake and exhaust ventilation slots to properly cool the
motor. If the power cord or plug to the handpiece is damaged, repair or replace
immediately. NEVER operate with a damaged power cord.

USE a dust collector (vacuum system) to pull sawdust, grinding dust, or other debris
away from the work area and the micro motor intake vents.

NEVER plug the Handpiece into the Variable Speed Foot Control Connection
Port on the back of the Control Box.

ALWAYS plug the Handpiece it into the Handpiece Connection Port on the
Front of the Control Box.

DO NOT operate the handpiece in the presence of any flammable liquid or gas.

Assembly Instructions

Do not plug into a power outlet before connecting the handpiece. Also, check to
see that the voltage selector switch (located on the back of the control box) is
set to the voltage to be used–110 or 220 volt.

Connecting Handpiece:

With the Power Switch in the “Off” position and the Rotation Selection Switch in the “Forward”
position, attach the micro motor handpiece to the control box by plugging the coiled cord into the
Handpiece Connection Port on the lower right side of the front control panel (Figure 1). Use keyway
for proper alignment when plugging in the cord. NEVER plug the handpiece into the Variable
Speed Foot Control Connection Port on Back of Control Box.

Always use the MH-011 handpiece in the forward direction. Never use in reverse.

Connecting Power Cord:

Before connecting the power cord plug (Figure 2) to a power outlet, select the proper voltage
(110 or 220v) on the voltage selector switch on the back of the control box. Put the On/Off Selector
Switch in the “OFF” position and turn the dial speed control to the “OFF” speed position. Put
the Rotation Selection Switch in the Forward Position. Operating the handpiece with
the switch in the reverse position can severely damage the handpiece.
Now plug in the
power cord to an AC current outlet. Refer to the section below for selecting the Hand/Foot and
Forward/Reverse switches.

Attaching Handpiece Accessories:

The MH-011 Hammer Handpiece comes with the following accessories and adapters:
3–10177K Anvil Points with Threaded Shanks
1– H8-32 Anvil Point Adapter for Threaded Anvil Point 10177K
1– H8-35 Adapter for Non-threaded Shank Accessories (2.35mm shank tools)
1– H8-214 Graver Holder with Allen Key
1– H8-38 Open End Wrench (5mm)
2–10562 Pins, used to tighten Anvil Points
1– H8-39 Anvil Point Holder (used for shaping the point )

Figure 1 Front Panel

Rotation
Selection
Switch

Handpiece
Connection
Port

Illuminated
Power
On/Off
Switch

Figure 2 Rear Panel

Dial Speed
Control

Speed Control
Selector Switch
(Hand or Foot)

Power
Cord

Voltage
Selector
Switch-110
or 220 volt

Variable Speed
Foot Control
Connection Port-
Foot Control
not included in
Kit 1011

On/Off Foot
Connection
Port

Overload
Indicator
Light

Operating Instructions
for HP4-917 Control Box

1. Power On/Off Switch:

When the Power On/Off Switch is in the ON position the switch
lever will light up. This switch must be in the ON position for
the handpiece to run with either the dial speed control or
the foot speed control selected.

Always turn the Dial and Power On/Off Switch to the Off position when not in use.

2. Hand or Foot Selector Switch:

With the Dial and Power On/Off Switch in the OFF position, select either foot or hand speed control.
With the Speed Control Selector Switch in the Hand position, the handpiece will run at the speed set
by the Dial Speed Control.

3. Forward/Reverse Rotation Selection Switch:

With the Power On/Off Switch in “OFF” position, select the “FORWARD” position. Do not change
handpiece direction while it is running and do not use in reverse.

4. Regulating Speed:

The Dial Speed Control varies the speed of the handpiece (impacts per minute) from minimum to
maximum when the Speed Control Selector Switch is in the Hand position.

Rotation
Selection
Switch

Handpiece
Connection
Port

Power
On/Off
Switch

Dial Speed
Control

Speed Control
Selector Switch
(Hand or Foot)

Overload
Indicator
Light

Three anvil points are
supplied so that the
tips can be shaped or
modified for different
setting operations. To

use the anvil points,

thread in the anvil point

adapter and tighten with wrench. Thread an anvil point in to it and tighten it with a pin in its cross
hole.

Texturing and beading tools with non-threaded 2.35mm shanks such as the pavé diamond point
(No. R146) can be used with the Adapter (No.H8-35) in the handpiece. Thread the Adapter into the
front of the handpiece and tighten with the wrench. Insert a 2.35mm shank tool into the adapter
and tighten the set screw with a Phillips screw driver.

The H8-214 Graver Holder screws into the front end of the handpiece and converts it into a power
engraving tool. It comes with a 5/64

″ allen key.

Impact Adjustment:

The force of impact can be increased or decreased by turning the metal ring while the handpiece is
either off or running. Test the impact on a piece of metal or material similar to the work piece until