9

PAM-510/520

ATT. ZONE AMPLIFIER

Connecting Speakers

Connecting Speakers

Before connecting speakers, disconnect the AC power cable. Note the proper connecting terminals as shown
below. Make certain that the total impedance is not less than the rated impedance indicated.

- CONNECTING HIGH-VOLTAGE DISTRIBUTED SPEAKER SYSTEMS

NOTE: Be sure that total impedance is not less than rated impedance. (See upper chart.)
WARNING: Extreme care must be exercised when connecting high-impedance systems, as potentially

hazardous voltages may be present at these terminals.

Do not install this equipment in a confined space with less-than-adequate ventilation.

Total rated input of up to 25W (PAM-510) or 50W (PAM-520)

When connecting a high-impedance(70V/100V) speaker system in parallel, you can connect speakers
with a total rated input of up to 25W (PAM-510) or 50W (PAM-520).

Output

4

SPK 1~5

Terminal

(LOW IMPEDANCE)

(HIGH IMPEDANCE)

Model Name

PAM-510

22V/4

Ω (120W)

EC & Associated : 100V/400

Ω (25W MAX)

USA/CANADA & Associated : 70V/196

Ω (25W MAX)

PAM-520

31V/4

Ω (240W)

EC & Associated :100V/200

Ω (50W MAX)

USA/CANADA & Associated : 70V/98

Ω (50W MAX)