JuiceGoose CQ Series - Power Sequencers User Manual

Page 7

Advertising
background image

REMOTE SWITCH CONNECTION

Although a Juice Goose CQ Series product can be remote controlled with a
Juice Goose RC-5 accessory or another CQ device, it can also be remote
activated with a simple contact closure using a switch or relay. The following
instructions are provided to assist with this configuration. This information is
also useful for assembling interface wiring going to and from the RJ type
cable specified for the CQ system.

SINGLE POLE DOUBLE THROW

LATCHING SWITCH

In the illustration below, connecting a single pole, double throw (SPDT)
switch to the signal input line of a CQ Series device will control the se-
quence up and down activity. Closing Pin 3 to Pin 7 will begin a sequence
UP. Closing Pin 4 to Pin 7 will begin a sequence DOWN. Closing both 3 and
4 to 7 will PAUSE. the sequence process. The control switch on the chassis
will be inoperative, except for the Manual On feature, when there is such a
contact closure on the input line.



1

2

3

4

5

6

7

8

C

Q

I

N
P

U

T

Advertising