Up down, Accel/decel 2 – KB Electronics KBDA-29 (1P) User Manual

Page 47

Advertising
background image

46

A4.

FORWARD/STOP AND REVERSE/STOP COMMAND

The Multi-Function Input Terminals can be used for remote Forward/Stop and Reverse/Stop operation

by connecting a switch or contact to any Multi-Function Input Terminal “1” – “7”, as shown in Figure

29, on page 47. When the “Forward/Stop” switch or contact is closed, the drive will run in the forward

direction and when the switch or contact is opened, the drive will stop. When the “Reverse/Stop”

switch or contact is closed, the drive will run in the reverse direction and when the switch or contact

is opened, the drive will stop.

Set Run/Stop-Forward/Reverse Control (Function No. 1.00) to External Contacts (“0001”). Set the

respective Multi-Function Input Terminal (Function Nos. 7.00 – 7.06), which will be used for

“Forward/Stop”, to “0006”. Set the respective Multi-Function Input Terminal (Function Nos. 7.00 –

7.06), which will be used for “Reverse/Stop”, to “0007”. In Figure 29, on page 47, Multi-Function Input

Terminals “4” and “7” have been arbitrarily chosen.

FIGURE 27 – UP/DOWN FREQUENCY CONTROL SWITCH OR CONTACT CONNECTIONS AND FUNCTION SETTINGS

14

4

16

1

15

TB1

2

17

3

18

9

21

5

19

6

20

7

22

8

23

26

10

24

11

25

12

27

13

28

Up Down

Function Settings

Function No.

Range/Code

2.00

Frequency

Control

0005

Up/Down

Using MFITs

7.03

Multi-Function

Input Terminal 4

0003

Up Frequency

Command

7.04

Multi-Function

Input Terminal 5

0004

Down Frequency

Command

7.14

Up/Down Frequency

Control Mode

0000 or 0001

Free-Running or

Incremental

7.15*

Increment of Up/Down

Frequency

0.01 – 30.00 Hz

Set to the Desired

Frequency

* Use with Function No. 7.14 code “0001” only.

A3.

ACCEL/DECEL 2

The drive provides a secondary Accel/Decel Time setting, which can be remotely selected with a

switch or contact connected to any Multi-Function Input Terminal “1” – “7”, as shown in Figure 28.

Set the respective Multi-Function Input Terminal (Function Nos. 7.00 – 7.06) to Accel/Decel 2 (“0005”).

The Accel/Decel 2 time is set in Function No. 7.16 (factory set to 1.5 seconds). When the switch or

contact is closed, the Accel/Decel 2 setting is selected. Accel/Decel 2 overrides the Accel and Decel

settings in Function Nos. 3.03 and 3.04. In Figure 28, Multi-Function Input Terminal “6” has been

arbitrarily chosen.

FIGURE 28 – ACCEL/DECEL 2 SWITCH OR CONTACT CONNECTION AND FUNCTION SETTINGS

16

15

1

TB1

26

21

Accel/Decel 2

17

2

3

18

5

4

19

20

6

22

7

8

23

10

9

24

25

11

14

27

12

13

28

Function Settings

Function No.

Range/Code

7.05

Multi-Function

Input Terminal 6

0005

Accel/Decel 2

7.16

Accel/Decel 2

Time

0.3 – 180.0

Set to the

Desired Time

Advertising