Using pliers, gently rock the female terminal back and forth

while pulling it upward. See Figure 17

6.2

MOTOR HORSEPOWER SELECTION (J2) – Set Jumper J2

to the corresponding position for the motor being used.

See Figure 18.

6.3

AUTOMATIC RIDE-THROUGH OR MANUAL START

SELECTION (J3)* – Jumper J3 is factory set to the “A” posi-

tion for Automatic Ride-Through. If the power is interrupted

for up to 2 seconds, the drive will shut down and then

“ride-through” and automatically return to the set frequency.

If Jumper J3 is set to the “M” position, the drive will have to

be manually restarted for a momentary power loss using the Start/Stop Switch. See Figure 19. Also

see Section 11.2, on page 22, for the Status (ST) LED indication.

*On Model KBAC-24D, Jumper J3 is labeled “AUTO” and “MAN”.

6.4

60 Hz AND 50 Hz MOTOR

OPERATION AND DRIVE

OUTPUT FREQUENCY

SELECTION (J4 AND J5) –

Both jumpers must be set for the

appropriate motor nameplate

frequency rating.

6.4.1 SETTING THE DRIVE

FOR 60 Hz OR 50 Hz

MOTOR OPERATION –

The drive is factory set to

operate 60 Hz motors.

Jumper J4 is factory set to

the “1X” position and

Jumper J5 is factory set to the

“60Hz” position. For 50 Hz motors,

set Jumper J5 to the “50Hz” posi-

tion, and be sure Jumper J4 is set to

the “1X” position. See Figure 20.

6.4.2 SETTING THE DRIVE FOR TWO

TIMES THE RATED MOTOR RPM –

The drive can also be used to oper-

ate the motor up to two times the

rated RPM. However, constant

horsepower will result when operat-

ing the drive in the “2X” mode

above the motor rated frequen-

cy. See Figure 21, on page 18.

For 120 Hz output with 60 Hz

motor, set Jumper J4 to the

“2X” position and be sure

Jumper J5 is set to the “60Hz”

position. For 100 Hz output with

50 Hz motor, set Jumper J4 to

the “2X” position and set

Jumper J5 to the “50Hz” position. See Figure 22, on page 18.

17

FIGURE 17 – REMOVING JUMPER J1

ON MODELS KBAC-24D, 27D

FIGURE 18 – MOTOR HORSEPOWER SELECTION

Terminal

Installed

Removed

Terminal

FIGURE 19 – AUTOMATIC RIDE-THROUGH

OR MANUAL START SELECTION*

Automatic Ride-Through

(Factory Setting)

(J3 Installed in “A” Position)

Manual Start

(J3 Installed in “M” Position)

A

J3

M

A

J3

M

J2

KBAC-24D KBAC-27D

1

2**

3/4

1

1

2

**

1/2

1

1/4

3/4

1/8

1/2

KBAC-29* KBAC-45* KBAC-48*

3***

3

5

2***

2

3

1

1

2

1

1

2

2

1

1

1

1

2

3/4

3/4

1

A

B

C

D

E

The factory setting is shown in bold.
*Jumper J2 on Models KBAC-29, 45, 48 is labeled “A”, “B”, “C”, “D”, “E”. **Model
KBAC-27D is rated 1

1

2

HP maximum with 115 Volt AC line input and 2 HP maximum

with 208/230 Volt AC line input. ***Model KBAC-29 is rated 2 HP maximum with
single-phase AC line input and 3 HP maximum with 3-phase AC line input.

FIGURE 20 – 60 Hz & 50 Hz MOTOR SELECTION

60 Hz Motor Operation

(Factory Setting)

(J4 Installed in “1X” Position)

(J5 Installed in “60Hz” Position)

50 Hz Motor Operation

(J4 Installed in “1X” Position)

(J5 Installed in “50Hz” Position)

2X

J4

1X

50Hz

J5

60Hz

2X

J4

1X

50Hz

J5

60Hz

*On Model KBAC-24D, Jumper J3 is labeled “AUTO” and “MAN”.

Advertising