RFI filtering is included as a standard feature. It greatly reduces conducted interference which could affect

sensitive equipment. The control contains barrier terminals as standard; however, quick disconnect

terminals can be provided as an option. A potentiometer (5K), isolated analog signal (0-10 VDC), or PWM

microprocessor output can be used to vary the output of the control.

TABLE 1 – ELECTRICAL RATINGS & MECHANICAL SPECIFICATIONS

Model KBWD-15 Rated 5.0 Amps DC @ 115 VAC 50/60 Hz

SPECIFICATIONS

Output Voltage Range (VDC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 – 130

Speed Range (Ratio) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50:1

Operating Frequency (kHz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >16

Form Factor (RMS / Avg Amps) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <1.05

Ambient Operating Range Temp (°C). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 – 45

Load Regulation (% Base Speed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1*

Timed CL Trimpot Range (TCL) (Seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 – 7

Acceleration Trimpot Range (ACCEL) (Seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 – 15

Minimum Speed Trimpot Range (MIN) (VDC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 – 40

Maximum Speed Trimpot Range (MAX) (VDC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 – 130

Current Limit Trimpot Range (CL) (% Range Setting) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 – 200

IR Comp Trimpot Range (IR) (VDC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 – 15

AC Line Voltage Regulation (% Base Speed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5

Analog Input Voltage (Voltage Following) (VDC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 – 10

Speed Potentiometer - 5 watt (Ohms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5K
*Based on motor having linear IR Comp characteristics.

PLUG-IN HORSEPOWER RESISTOR

®

A Plug-in Horsepower Resistor

®

must be installed to match the control to the motor

horsepower and armature current. See table 2, p. 5 for the correct value.

Plug-in Horsepower Resistors

®

are stocked by your distributor.

CAUTION: Be sure Plug-in Horsepower Resistor

®

is inserted completely into

mating socket.

3

FIG. 1 – CONTROL LAYOUT

Illustrates factory setting of jumpers and approximate setting of trimpots