KB Electronics KBWT-210 User Manual

Page 2

Advertising
background image

KBWT Series Installation and Operation Instructions

(A40130) – Rev. B00 – 5/29/2013

Page 2 of 7

TABLE 1

GENERAL PERFORMANCE SPECIFICATIONS

Description

Specification Factory

Setting

Models KBWT-16, 110, 112 AC Line Input Operating Range (Volts AC, 50/60 Hz)

115 (± 15%)

──

Models KBWT-26, 210 AC Line Input Operating Range (Volts AC, 50/60 Hz)

208 (-15%) / 230 (+15%)

──

Speed Range (Ratio)

50:1

──

Field Voltage for Models KBWT-16, 110, 112 (for Shunt Wound Motors Only) (Volts DC)

100 / 50

──

Field Voltage for Models KBWT-26, 210 (for Shunt Wound Motors Only) (Volts DC)

200 / 100

──

Operating Frequency (kHz)

>16

──

Form Factor (RMS/AVG Amps)

<1.05

──

AC Line Load Regulation (% Base Speed)

0.5

──

Load Regulation (% Base Speed)

1*

──

Analog Input Voltage (Voltage Following) (Volts DC)

0 – 5

──

Voltage Following Linearity (% Base Speed)

±5

──

Main Speed Potentiometer (5 Watts)

5 kΩ

──

Fixed Timed Current Limit (I X t) (Seconds)

3, 5, 10

3

Current Limit (CL) Trimpot Range (% Full Load)

0 – 200

150

IR Compensation (IR) Trimpot Range at Full Load (Models KBWT-16, 26) (Volts DC)

0 – 15

6

IR Compensation (IR) Trimpot Range at Full Load (Models KBWT-110, 112, 210) (Volts DC)

0 – 15

3

Maximum Speed (MAX) Trimpot Range (% Base Speed)

50 – 100

100

Minimum Speed (MIN) Trimpot Range (% Base Speed)

0 – 30

0

Acceleration (ACCEL) Trimpot Range (Seconds)

0.2 – 12

2

Deceleration (DECEL) Trimpot Range (Seconds)

0.2 – 12

2

Operating Temperature Range (°C / °F)

0 – 40 / 32 – 104

──

Operating Humidity Range (% Relative, Non-Condensing)

0 – 95

──

Storage Temperature (°C / °F)

-25 – +85 / -13 – +185

──

*Based on a motor having linear IR compensation characteristics.

TABLE 2

ELECTRICAL RATINGS

Maximum Horsepower

AC Line Input

Output

Continuous

Duty

Intermittent

Duty

(1 Minute)

Continuous Duty Rating

Model No. Part No. HP (kW)

HP (kW)

Volts AC

(50/60 Hz)

Maximum

Current

(Amps RMS)

Fuse or

Circuit

Breaker

Rating

(Amps AC) Amps DC Volts DC Amps DC Volts DC

Armature

Fuse

(Amps DC)

KBWT-16

8614

0.75 (0.5)

1.5 (1.1)

115

10

15

6.0

90

6.0

130

10.0

KBWT-26

8615

1.5 (1.1)

3.0 (2.0)

208/230

10

15

6.0

180

6.0

200

10.0

KBET-110 8603

1.2 (0.9)

2.0 (1.5)

115

15

20

10.0

90

8.5

130

15.0

KBWT-112 8612

1.5 (1.1)

2.5 (1.9)

115

18

25

12.0

90

10.5

130

20.0

KBWT-210 8610

2.2 (1.7)

4.0 (3.0)

208/230

15

20

10.0

180

8.5

200

15.0


WARNING! This drive has been factory Hi-Pot tested. If you choose to perform another Hi-Pot test on the
drive, there is a risk that the drive can be damaged. Contact our Sales Department.



2 MOUNTING INSTRUCTIONS
The drive should be mounted on a flat surface and located in an area where it will not be exposed to
contaminants such as water, metal chips, solvents, or excessive vibration. When mounting the drive in an
enclosure, the enclosure should be large enough to allow proper heat dissipation so that the ambient temperature
does not exceed 40 °C (104 °F) at full rating. See Figure 1, on page 3.


Advertising
This manual is related to the following products: